Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Int J Cardiol ; 401: 131820, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38307419

RESUMEN

BACKGROUND: Post-myocardial infarction ventricular septal rupture (VSR) is a rare and severe complication of myocardial infarction. To find early mortality (<30 days) risk factors of device VSR closure and to evaluate its medium-term outcome. METHODS: Multicenter retrospective analysis on all 46 consecutive patients with percutaneous (n = 43) or hybrid (n = 3) VSR closure in 2000-2020 with various nitinol wire mesh occluders. Medical records, hemodynamic data, procedure results, short- and mid-term follow-up were analyzed (4.8 ± 3.7 years, range: 0.1-15, available in 61.7% of patients). Of the patients, 34.8% underwent VSR closure in acute phase (<21 days after VSR occurrence), 17.4% underwent device closure due to significant residual shunt after previous VSR surgery. RESULTS: Success rate was 78.3%. More than moderate residual shunt, major complications, and early surgical reintervention affected 18.9%, 15.2% (including 2 intra-procedural deaths), and 21.7% of patients, respectively. Early mortality was 26.1% (13.9% in successful vs. 70% in unsuccessful closure; p < 0.001). Older age, need for intra-aortic balloon counterpulsation, severe complications, and procedural failure were identified as risk factors for early mortality. Among patients who survived the early period, the 5-year survival rate was 57.1%. NYHA class improved in 88.2% patients at the latest follow-up. CONCLUSIONS: Procedure of VSR device closure demonstrates an acceptable technical success rate; however, the incidence of severe complications and early mortality is notably high. Older patients in poor hemodynamic condition and those with unsuccessful occluder deployment are particularly at a higher risk of a fatal outcome. The prognosis after early survival is promising.


Asunto(s)
Infarto del Miocardio , Rotura Septal Ventricular , Humanos , Rotura Septal Ventricular/diagnóstico , Rotura Septal Ventricular/etiología , Rotura Septal Ventricular/cirugía , Estudios Retrospectivos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/cirugía , Infarto del Miocardio/complicaciones , Factores de Riesgo , Pronóstico , Resultado del Tratamiento
3.
Kardiol Pol ; 81(3): 259-264, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36594530

RESUMEN

BACKGROUND: Transcatheter closure of atrial septal defect (ASD) has become the treatment of choice for most patients. About 5% of them suffer from transient headache episodes (THE) after the procedure, whose etiology is unclear. AIMS: To evaluate risk factors for THE occurrence after transcatheter closure of ASD in the pediatric population. METHODS: Eight hundred and forty patients, after transcatheter ASD closure with nitinol devices, from a single center, were included in retrospective analysis. THE was defined as occurring up to 24 hours after the procedure. A logistic regression model including age, weight, ASD diameter, device size, presence of nitinol coating on the device, fluoroscopy time, application of balloon calibration, device oversizing, and residual shunt after 24 hours was created to evaluate risk factors for THE occurrence. RESULTS: There were 40 patients with THE (4.8%), 70% female and 30% male. The median age was 13 (7.35-16) years. In patients with headache, balloon calibration (BC) was performed more frequently (82.5% vs. 43.3%; P <0.001). The balloon waist median (interquartile range [IQR]), 19 (16-22) mm vs. 15 mm (12-18) mm (P <0.001), and device size median (IQR), 18 (13.5-22) mm vs. 14 (11-17) mm (P <0.001) were larger, and residual shunt after 24 hours (12.5% vs. 4.9%; P = 0.03) and a year (7.5 vs. 1.0%; P <0.001) were more frequent. ASD size and the prevalence of double/multiple ASD were similar in both groups. Age, BC application, no nickel release protection, duration of fluoroscopy, and device oversizing were predictors of THE (P <0.001). CONCLUSIONS: BC during percutaneous ASD closure and the lack of a protective layer against nickel release on the device are risk factors for headache occurrence in the early postprocedural period.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Humanos , Niño , Masculino , Femenino , Adolescente , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios Retrospectivos , Defectos del Tabique Interatrial/cirugía , Defectos del Tabique Interatrial/etiología , Cefalea/etiología , Resultado del Tratamiento , Ecocardiografía Transesofágica , Dispositivo Oclusor Septal/efectos adversos
4.
Postepy Kardiol Interwencyjnej ; 18(2): 154-161, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36051839

RESUMEN

Introduction: Balloon aortic valvuloplasty (BAV) is a common treatment method of aortic valve (AV) stenosis in neonates. Long-term BAV effects are suboptimal, and their predictors are not well acknowledged. Aim: To identify predictors of suboptimal short- and long-term BAV results. Material and methods: The study group comprised forty-three neonates (8 females; weight 3.34 ±0.56 kg) who underwent BAV between 1998 and 2021. Seventeen patients (39.53%) had critical AV stenosis. AV was bicuspid in 22 patients, tricuspid in 12, unicuspid in 2, and undefined in 7 patients. The mean balloon/annulus ratio was 0.9 ±0.07. Catheterization, clinical, and follow-up data were analysed. Results: The peak-to-peak gradient decreased from 67.5 ±26.3 to 21.3 ±12.6 mm Hg. Twenty-eight patients (65.1%) had adequate early outcome. Aortic regurgitation (AR) occurred in 13 (30.2%) patients. No predictors of inadequate early outcome were found. Twenty-year survival was 90.7%. Eleven (35.5%) patients underwent reintervention at a median of 12 (1-215) months; BAV in 5 patients, surgical valvuloplasty in 2, Ross operation in 2, AV replacement in 1, and Norwood operation in 1 patient. Fifteen-year freedom from reintervention (FFR) was 48%. Adequate early outcome resulted in higher FFR (71% vs. 22%), and so did no significant AR (60% vs. 30%). Conclusions: BAV provides satisfying early results. AR remains a significant aftermath of BAV. Risk factors and procedural techniques improving the outcome of BAV are unclear. Further research is needed to improve FFR.

9.
Kardiol Pol ; 79(3): 287-293, 2021 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-33599452

RESUMEN

BACKGROUND: Transcatheter patent ductus arteriosus (PDA) closure has become the first­choice method of treatment in the majority of patients. However, device selection poses a challenge. AIMS: This study aimed to analyze periprocedural and 1­year outcomes of PDA transcatheter closure performed with different devices throughout a 25­year time period in a single center. METHODS: All 1036 patients who underwent transcatheter PDA closure between 1993 and 2020 were included in retrospective analysis. Various devices were used: the Rashkind device (RD; n = 25), coils (n = 469), nitinol duct occluders type I (DO I; n = 300), type II (n = 32), type II additional sizes (ADO II AS; n = 209), as well as off­label devices: vascular plugs and atrial septal and muscular ventricular septal defect occluders (n = 17). Data on 24­hour and 1­year follow­up were available for 100% and 78.9% of the study patients, respectively. RESULTS: The procedure was successful in 98.6% of the study patients, with a major complication rate of 0.2%. Complete PDA closure after a year was observed in 81.8% of the patients treated with RD, 93.7% of those with coils, and 100% of those with duct occluders. There were no differences between Amplatzer DO I (n = 159) and its DO I copies manufactured in China (n = 141) with regard to success, efficacy, and complication rates. Recently, ADO II AS has replaced coils and become the preferred device to close small­to­moderate PDA. CONCLUSIONS: Transcatheter PDA closure with all types of nitinol duct occluders is safe and effective, with no residual shunting at 1­year follow­up. Due to higher efficacy, ADO II AS has replaced coils in the treatment of smaller PDA.


Asunto(s)
Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Cateterismo Cardíaco , China , Conducto Arterioso Permeable/cirugía , Humanos , Lactante , Estudios Retrospectivos , Resultado del Tratamiento
10.
Kardiol Pol ; 78(10): 1066-1083, 2020 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-33016689

RESUMEN

Atrial septal defect is the most common congenital heart lesion in adults. Although atrial septal defect closure is recommended in those with right heart enlargement or paradoxical embolism, data informing such indications in adults are quite limited. This population has many unique characteristics and needs. In recent years, significant progress has been made with regard to diagnostic modalities that facilitate the diagnostic workup of these patients. However, the decision­making process, especially in selected adult patients population (advanced age, various concomitant diseases, poor LV function [both systolic and diastolic], pulmonary hypertension, concomitant arrhythmias or multiple defects, or deficient rims) is still not easy. Available data are predominantly focused on imaging endpoints and short­term morbidity and mortality rather than long­­term. The evidence base for outcomes with or without defect closure comes from various studies with different observation periods. Moreover, the clinical experience in diagnosing and treating that subgroup of patients is inhomogeneous between individual physicians (cardiologists, imaging specialists, operators) and between small and large experience centers. In the view of the above, the joint group of experts from the Association of Cardiovascular Interventions and the Grown­Up Congenital Heart Disease Section of the Polish Cardiac Society developed the following consensus opinion in order to standardize the principles of diagnosis, indications for treatment, methods of performing procedures, and tenets of postoperative care in Poland.


Asunto(s)
Cardiopatías Congénitas , Defectos del Tabique Interatrial , Cateterismo Cardíaco , Consenso , Cardiopatías Congénitas/cirugía , Defectos del Tabique Interatrial/cirugía , Humanos , Polonia , Resultado del Tratamiento
11.
Kardiol Pol ; 78(9): 950-951, 2020 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-32988181

Asunto(s)
Cardiología , Niño , Humanos , Polonia
13.
J Interv Cardiol ; 2020: 4585124, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32410916

RESUMEN

OBJECTIVES: Patent ductus arteriosus (PDA) in elderly patients is an uncommon anomaly, and the duct itself is often calcified and fragile; therefore, transcatheter closure is more difficult. The aim is to analyse periprocedural and one-year follow-up results of transcatheter closure of PDA in such patients. Methods and results. Retrospective analysis of 33 elective patients aged ≥55 years (median 63; 56-85; 29 women), in whom PDA was closed percutaneously between 2002 and 2018 in two tertiary centres. All but three patients were symptomatic, with most in NYHA II (n = 14) and III (n = 11) class; pulmonary hypertension (n = 22), arterial hypertension (n = 22), duct calcifications (n = 17), atrial fibrillation (n = 15), significant mitral regurgitation (n = 5), and decompensated renal failure (n = 2) were observed. Different devices were applied depending on PDA morphology; nitinol wire mesh occluders with symmetrical articulating discs have been the most used in recent years (n = 11). Follow-up was conducted at an outpatient clinic (28/33 patients). The procedure was successful in all patients. There was one embolisation, followed by implantation of a larger device. No major complications were noted. A small residual shunt was present in echocardiography in one patient after one year. NYHA class improved in all but two patients (with multiple comorbidities). CONCLUSIONS: Transcatheter PDA closure in elderly patients is safe and efficient with a high complete closure rate and few complications. Amplatzer duct occluder type II is an attractive device in such patients.


Asunto(s)
Cateterismo Cardíaco/métodos , Conducto Arterioso Permeable/cirugía , Complicaciones Posoperatorias , Implantación de Prótesis , Dispositivo Oclusor Septal , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Estudios Retrospectivos , Resultado del Tratamiento
18.
J Cardiol ; 74(4): 381-387, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31023567

RESUMEN

BACKGROUND: We aimed to evaluate medium- and long-term outcomes of transcatheter closure (TC) of ruptured sinus of Valsalva aneurysm (RSVA), which is a rare and mostly congenital heart disease. METHODS: Retrospective analysis included 23 patients (14 males) aged 15-79 years (y; 39.9±18.5) selected for TC of RSVA between 2007 and 2017 in two tertiary centers in Poland and Ukraine. Fifteen patients were in New York Heart Association (NYHA) class III or IV before TC; 5 patients had acquired RSVA after previous cardiac surgery. We applied 22 duct, 3 muscular, and 1 atrial septal Amplatzer or Amplatzer-like occluders by the anterograde venous approach after arterio-venous loop creation in all but 1 patient. Mean follow-up conducted in outpatient clinic was 5.5±3.5 (1-11)y. RESULTS: The procedure was successful in 19/23 patients (82.6%). Four procedures were abandoned and the device percutaneously retrieved due to coronary artery compression (1 patient), transient increase of aortic regurgitation (AR; 1 patients) or embolization (2 patients). New onset of significant AR was noted in one of the latter patients after device removal. NYHA class improved in all treated patients but 2, in whom it remained stable (p<0.05), with 10 patients in class I. Three patients needed percutaneous re-intervention during follow-up because of significant residual shunt in 1 and late recurrent RSVA in 2 patients. The follow-up of the remaining patients was uneventful. Neither erosion, embolization, new AR, nor death were observed. CONCLUSIONS: The percutaneous closure of RSVA is a safe and effective method of treatment with good clinical outcome. However, although not described previously, recurrent shunts after TC of RSVA are possible and can be treated successfully with another transcatheter intervention.


Asunto(s)
Rotura de la Aorta/cirugía , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Seno Aórtico/cirugía , Adolescente , Adulto , Anciano , Cateterismo Cardíaco/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polonia/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Ucrania/epidemiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...